Drzwi z panelami szklanymi
Perfect for a panoramic lift installation
Drzwi z panelami szklanymi
Glass panels doors give any installation a distinctive style; they are perfect for a panoramic lift installation, but can also offer more openness and light to a closed shaft lift.
The current standard allow you the utilisation of new solutions representing the maximum as far as safety, design and elegance concerns matching innovation and cost saving.
The doors are supplied in any kind of configuration and are available in two, three, four and six panels.
Drzwi z panelami "Szkło w ramkach"
Estetyczne i wytrzymałe
Drzwi z panelami "Szkło w ramkach"
Glass-framed panels doors may restore with class any installation, from the panoramic one to the installations with closed shaft.
DiscoverOgnioodporne drzwi z panelami przeszklonymi
Norma EN 81-58 klasa "E"
Ognioodporne drzwi z panelami przeszklonymi
DiscoverDrzwi ognioodporne klasy E
EN 81-58
Drzwi ognioodporne klasy E
The fire resistant lift landing doors are the most diffused in Europe and in the world.
DiscoverDrzwi ognioodporne klasa "EW"
Norma EN 81-58
Drzwi ognioodporne klasa "EW"
The fire resistant lift landing doors are the most diffused in Europe and in the world. Their essential feature is to satisfy the fire resistance requirements of the fireproof rules for the buildings.
DiscoverDrzwi ognioodporne klasa "EI"
Norma EN 81-58
Drzwi ognioodporne klasa "EI"
The fire resistant lift landing doors are the most diffused in Europe and in the world. Their essential feature is to satisfy the fire resistance requirements of the fireproof rules for the buildings.
DiscoverDrzwi zgodne z DIN 18091
Drzwi szybowe ze skrzydłami "skrzynkowymi"
Drzwi zgodne z DIN 18091
The fire resistant landing doors according to DIN 18091 standard are mainly produced for the German market and for all the countries where these standards are accepted.
DiscoverSpecjalne ramy
Ościeżnice z profili i blach
Specjalne ramy
These particular types of frames are designed to simplify the modernization of existing lifts.
DiscoverInstalacje eksplozjo-odporne
Instalacje eksplozjo-odporne
A mechanism or operator in explosionproof execution is able to avoid the triggering of sparks, according to 1127:1997 standards
DiscoverInstalacje IP54
Instalacje IP54
DiscoverWittur zakończył proces certyfikacyjny dla drzwi wandlo - odpornych
zgodnie z EN 81-71:2018
Wittur zakończył proces certyfikacyjny dla drzwi wandlo - odpornych
DiscoverDrzwi do zastosowań morskich
Drzwi do zastosowań morskich
These doors combine technological research with aesthetics with an high level of customization.
DiscoverDrzwi standardowe
Drzwi standardowe
Wittur realizes a wide range of doors in standard execution supplying ideal solutions for each and every market requirement.
DiscoverDrzwi do dźwigów dla ekip pożarówych zgodne z EN 81-72:2003
Drzwi do dźwigów dla ekip pożarówych zgodne z EN 81-72:2003
A Firefighter Elevator is a system that, in standard conditions, is used by passengers, while, in event of fire, it is used by Firefighters who can change its operating mode thanks to special controllers
DiscoverWandaloodporne drzwi windy EN 81-71 kategorii 2
Wandaloodporne drzwi windy EN 81-71 kategorii 2
Wittur Pegasus range of landing and car door types are available with full compliance to the vandal-resistant certification category 2 according to EN 81-71 European standard.
DiscoverProduct Comparison Tool
| Augusta Evo |
C-MOD |
Hydra |
B-HR |
B-G |
Fineline® |
ECO BUS |
MOD KITS |
Luna |
Nettuno |
Taurus |
SWS |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Up to 2 m/s |
Up to 2 m/s |
Up to 4 m/s |
Starting from 5 m/s |
Up to 3 m/s |
Up to 2 m/s |
Up to 4 m/s |
Up to 3 m/s |
Up to 3 m/s |
Up to 3 m/s |
Up to 3,5 m/s |
Up to 2 m/s |
Clear opening (mm) |
700 - 1100 |
600 - 1400 |
700 - 1600 |
700 - 2400 |
700 - 3500 |
600 - 900 |
600 - 3500 |
600 - 1800 |
600 - 3200 |
800 - 5000 |
800 - 1200 |
500 - 1100 |
Clear height (mm) * |
2000 - 2200 |
2000 - 2300 |
2000 - 2600 |
2000 - 3000 |
2000 - 3500 |
1900 - 2100 |
1900 - 3500 |
2000 - 3500 |
1900 - 3500 |
2000 - 5000 |
2000 - 2200 |
2000 - 2100 |
C2 / Sill package (mm) |
130 |
117 |
180 |
200 |
165 |
85 |
Underdriven 186 / Top driven 180 |
180 |
75 |
240 |
— |
|
T2 / Sill package (mm) |
180 |
185 |
210 |
270 |
255 |
115 |
|
— |
270 |
123 |
290 |
— |
T3 / Sill package (mm) |
— |
273 |
256 / 302 |
— |
345 |
— |
|
— |
— |
182 |
— |
— |
C4 / Sill package (mm) |
— |
185 |
210 |
270 |
255 |
Asymmetrical 115 |
|
— |
270 |
123 |
— |
130 |
C6 / Sill package (mm) |
— |
— |
302 |
— |
345 |
— |
— |
— |
— |
182 |
— |
— |
T1 / Sill package (mm) |
— |
— |
180 |
— |
— |
— |
— |
Underdriven 186 / Top driven 180 |
180 |
— |
— |
— |
Full glass |
— |
|
|
|
— |
|
|
|
— |
— |
||
Framed Glass |
— |
|
|
|
— |
|
|
|
|
— |
||
EN 81-20/50 |
|
|
|
|
|
|
|
|
|
|
||
EN 81-71 |
— |
Cat. 1 |
Cat. 1 |
Cat 1 |
Cat 1, Cat 2 |
— |
— |
Cat.1 |
— |
— |
Cat 1, Cat 2 |
— |
EN 81-72 |
— |
|
|
|
— |
— |
— |
|
|
|
— |
|
EN 81-58 E |
|
|
|
|
|
|
|
|
|
— |
||
EN 81-58 EI |
|
|
|
— |
|
— |
— |
|
|
— |
||
BS 476 E |
|
|
|
— |
|
|
|
|
— |
— |
||
GOST |
— |
|
|
|
— |
|
— |
— |
— |
— |
— |
|
Aluminium sill |
|
|
|
|
|
— |
— |
— |
|
|
||
Reinforced sill |
— |
|
|
|
— |
|
|
|
|
|
— |
|
Hidden sill |
— |
— |
|
|
— |
|
|
|
— |
|
— |
|
Door closing |
Spring |
Spirator |
Counterweight |
Counterweight |
Counterweight |
Counterweight |
Various |
Spring |
Spirator |
Counterweight |
Spirator |
Spring |
Light curtain |
Fixed |
Fixed |
Fixed and dynamic |
Fixed and dynamic |
Fixed and dynamic |
Fixed |
Fixed and dynamic |
Fixed and dynamic |
Fixed and dynamic |
Fixed and dynamic |
Dynamic |
Fixed |
IP54 |
— |
|
|
|
— |
|
|
|
|
|
— |
|
Door Drive |
ECO+ |
SZS / SDS |
ECO+ |
SDS |
SDS SDS MV |
ECO+ |
Various |
SUPRA |
MIDI+ SUPRA |
Industrial motor |
SDS, SWS + IRDA |
ECO+ |